Chimney Flashing & Cricket Leaks in Celina, TX: Causes, Code Basics, and Who to Call

How chimney flashing and crickets keep water out, why the joint where a chimney meets the roof is one of the most common leak spots, and what to ask before anyone patches it. For homeowners in Celina, Prosper, Anna, Melissa, and Princeton. Educational only. It is not an inspection, a repair estimate, or a contractor quote. Updated November 19, 2026.

A chimney is one of the biggest holes in a roof. InterNACHI's roof inspection series puts it plainly: the point where the chimney penetrates the roof "is basically a big hole in the roof," and no matter what the chimney is made of, that opening has to be sealed with flashing. Left long enough, metal flashing corrodes and leaks; installed incorrectly, it can leak right away.

Below: how chimney flashing is supposed to be layered, what a cricket is and when the code calls for one, the shortcuts that cause most leaks, framed chases with metal tops, clues you can check from the ground and the attic, hail and re-roof points, and who to call. Sources are listed at the bottom. No prices are quoted, because the honest answer depends on what actually failed.

The short version for Celina homeowners

  • Three metal layers do the work: apron flashing below, step flashing woven into the shingles on the sides, and counter-flashing set into the brick.
  • Chimneys wider than 30 inches across the slope need a cricket under the model IRC (R903.2.2). Celina builds to the 2024 codes.
  • Caulk is maintenance, not a fix. If the only plan is more sealant, ask what is underneath.
  • Spring and October test the flashing. May is the wettest month at McKinney's airport (5.15 in. on average, 2005–2025); July and August are the driest. Rain table.
  • Wind direction matters. Strong gusts near Celina come most often from the south and from the west through northwest, which pushes rain against those faces of a chimney. Wind data.
  • Dry it within 24–48 hours (EPA), then keep a leak log for whoever inspects it.
  • After a big storm, two trades may be needed: a roofer for flashing and cricket, a chimney professional for the cap, crown, flue, and liner.

The layers that keep a chimney dry

The U.S. Department of Energy's Building Science Education page on waterproofing chimneys calls the chimney "one of the largest penetrations in a residential roof assembly" and describes the metal flashing as three elements working together:

  • Base (apron) flashing on the downhill face, which laps over the shingles below so water steps down onto the roof.
  • Step flashing along the sides: short, overlapping pieces woven into each shingle course. InterNACHI's sidewall flashing article says all shingle manufacturers require step flashing at sidewalls, and that continuous one-piece flashing used with shingles is a defective installation.
  • Counter-flashing set into the brick or stone that laps down over the base and step flashing, so water running down the chimney face cannot get behind them. InterNACHI's counter-flashing article describes the correct method on brick: sections inserted into the mortar joints (or a groove cut into the brick), then sealed.

The rule underneath all of it, from InterNACHI's asphalt shingle flashing article: on the uphill side the flashing is overlapped by the roofing, and on the downhill side the flashing overlaps the roofing. Water should always be stepping down onto the next layer, never running behind it. The uphill side of a chimney is where that gets hard, which is why crickets exist.

What a chimney cricket does

A cricket (or saddle) is a small peaked roof built on the uphill side of the chimney. InterNACHI's chimney inspection article describes it as "a small roof designed to keep runoff from pooling on the uphill side of the chimney." Without one, everything that runs down the slope above a wide chimney, including rain, leaves, and grit, piles into a flat pocket against the brick and sits there.

The model building code sets a size trigger. Section R903.2.2 of the International Residential Code (2024 edition text, as published on UpCodes; the official ICC chapter 9 is the reference) says a cricket or saddle "shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular to the slope," and that its covering must be sheet metal or the same material as the roof. The one exception is for unit skylights flashed to the manufacturer's instructions.

The City of Celina's Building Services page lists the 2024 International Codes, including the IRC, as its adopted codes effective February 2026. Cities adopt codes with local amendments, so if the exact requirement matters for your project, ask the City's permit desk or have your roofer confirm it.

Points worth knowing about crickets:

  • A cricket makes two little valleys. InterNACHI notes that framing a cricket creates a couple of small valleys that have to be flashed correctly. Those valleys, and the joint where the cricket meets the chimney, are leak points of their own.
  • Debris speeds up corrosion. The same article shows cricket valley flashing with corrosion and packed debris, and says debris holds moisture against the metal, so corrosion advances faster there. Overhanging trees make this worse.
  • A missing cricket is reportable. InterNACHI tells inspectors that when a chimney that should have a cricket doesn't, they should say so in the report and explain why crickets are a good idea.
  • Narrow chimneys are not exempt from leaks. Under 30 inches the code does not require a cricket, but the uphill flashing (sometimes called the back pan or head flashing) still has to direct water around the chimney. Ask what is installed there.

The shortcuts behind most chimney leaks

InterNACHI's chimney flashing article says brick and stone chimneys have the same problem as brick and stone walls: getting the counter-flashing right. It explains that because counter-flashing on brick and stone is so often done with sealant only, "the incorrect practice has become what's normal." Common conditions to ask about:

  • Sealant-only counter-flashing. Metal stuck or caulked to the face of the brick instead of set into a mortar joint or cut groove. InterNACHI says sealant eventually dries, shrinks, and cracks and should be checked every year and re-applied as needed.
  • Gaps in the mortar joints. The counter-flashing article shows flashing set into joints that were never properly filled, and flashing that was neither sealed nor fastened, leaving a path for water behind it.
  • Missing counter-flashing. InterNACHI's example of it "just missing" leaves the top edge of the step flashing open to every rain.
  • Continuous flashing on the sides in place of step flashing on a shingle roof.
  • Stone chimneys "flashed" with gobs of sealant. InterNACHI says this is how stone sidewalls are most often done, even though the correct method extends counter-flashing up behind the stone.

If a contractor's plan for a leaking chimney is "we'll caulk it," ask what is under the sealant and whether the step and counter-flashing are actually there. Our guide to hiring a roofer in Celina covers the paperwork and questions to ask.

It is not always the flashing

The Chimney Safety Institute of America (CSIA) says water causes more damage to masonry chimneys than fire, and that it usually happens slowly enough to be ignored until the problem is serious. Its four prevention points cover more than the roof joint:

  • Chimney cap to keep rain (and birds and animals) out of the flue.
  • Crown in good repair. CSIA says crowns should project beyond all sides by two inches to protect the brick and mortar below.
  • Flashing, the seal between the roofing and the chimney.
  • Waterproofing the masonry. CSIA notes that common brick acts like a sponge, and defective mortar joints make it worse.

That is why a stain near the chimney sometimes needs two trades: a roofer for the flashing and cricket, and a chimney professional for the cap, crown, flue, and masonry. InterNACHI's chimney articles also cover cracked mortar caps, which it recommends sealing and checking every year.

Framed chases with metal tops

Not every "chimney" is brick all the way down. Factory-built fireplaces often vent through a framed chase, clad in siding, stone, or brick veneer, with a sheet-metal chase pan (chase cover) on top. CSIA's Level 2 inspection guide for factory-built fireplaces tells sweeps to inspect the storm collar, rain cap, and flashing; to look for rust, low spots, or pinholes that let water sit on the chase pan; to inspect any cricket; and, if the chase is wider than 30 inches and does not intersect the ridge, to recommend a cricket.

The practical takeaway: on a framed chase, water can come in through the top (a rusted or sagging pan), through the siding or veneer on the chase walls, or at the roof joint. A roofer can speak to the roof joint and cricket; the top of the chase and the venting are usually chimney or fireplace work.

Clues to check before you call

Stay off the roof. From the ground, binoculars and photos go a long way. From inside:

  • Where the stain is. Ceiling or wall stains beside the fireplace, or on the ceiling just downhill of the chimney, point toward the roof joint. Water inside the firebox or a rusty damper can point more toward the cap, crown, or flue (CSIA lists rusted dampers among the results of chimney water penetration).
  • When it happens. Note the date, how hard it rained, and which way the wind blew. A chimney that leaks only in wind-driven rain from one direction is a strong clue for whoever inspects it.
  • The attic. CSIA's Level 2 masonry chimney guide tells inspectors to look for water damage "especially just below the flashing." If you can safely see the chimney from the attic, look for dark or stained sheathing and framing around it. InterNACHI also suggests checking around sealant-dependent flashing from the attic.
  • What you can see from the ground. Shiny caulk lines or roof cement smeared on the brick, flashing pulled away from the chimney, rust on a metal chase top, or a flat, debris-filled pocket on the uphill side of a wide chimney.
  • White staining on brick. InterNACHI notes that white efflorescence on brick and mortar is caused by moisture (in its example, flue condensation) and that over time it can deteriorate a chimney. Mention it if you see it.

If water is actively coming in, limit damage inside and see our emergency roof tarp guide for safe first steps while you wait for a roofer.

If water is already inside: the first 48 hours

The EPA's Brief Guide to Mold, Moisture and Your Home is blunt about timing: "It is important to dry water-damaged areas and items within 24-48 hours to prevent mold growth," and if wet or damp materials are dried within that window, "in most cases mold will not grow." The same guide says the key to mold control is moisture control, so fixing the leak matters as much as cleaning up after it.

  • Catch and move. Put a bucket under the drip, move furniture and rugs, and pull wet items off the hearth.
  • Photograph before you clean. Wide shots of the room plus close-ups of the stain, with the date. If the roof was damaged in a storm, the Texas Department of Insurance advises photos and video of the damage and keeping receipts for temporary repairs.
  • Check the attic if it is safe. Wet insulation or dark sheathing next to the chimney tells you water is getting past the roof layer, not just running down the inside of the flue.
  • Hold off on the fireplace. CSIA lists rusted dampers, rotted wood, and cracked flue liner systems among the results of chimney water penetration. Have the firebox and flue looked at before the next fire.
  • Do not patch the roof yourself in the rain. Stay off wet or steep roofs. A tarp or temporary repair is a job for a roofer; our tarp guide explains what a proper one looks like.

Keep a leak log for whoever inspects it

Chimney leaks are hard to trace because the water can enter at one point and show up several feet away. The single most useful thing you can hand a roofer or chimney professional is a record of when the leak shows up and when it does not. Copy this into a notes app and add a line every time it rains:

DateRain (light / steady / heavy)Wind directionWhere water or stain appearedFireplace in use?Photo taken?
e.g. Apr 12Heavy, about 1 hourFrom the south, gustyCeiling left of the fireplace, new dripNoYes
e.g. Apr 20Steady, all dayLight from the northNo new waterNoYes (dry)

Dry days count too. A chimney that leaks only when rain is driven from one direction points toward the flashing on that face. One that leaks in any steady rain, wind or not, points more toward the cap, crown, or masonry. Stains that appear during cold snaps with no rain at all can be condensation rather than a roof leak, which is a chimney or venting question. You can look up the wind direction for any past date from the National Weather Service records for McKinney National Airport, the nearest airport station to Celina.

When Celina's rain tests chimney flashing

A flashing defect does not leak every time it rains. It leaks when there is enough water, for long enough, hitting the right face of the chimney. To see when that happens here, we pulled 21 years (2005–2025) of NOAA daily observations for McKinney National Airport (KTKI), about 15 miles southeast of downtown Celina, from the Regional Climate Centers' ACIS service. Celina itself has no long-running official weather station, so treat these as a close regional stand-in, not a reading from your street.

MonthAvg. rain (in.)Days with any rainDays with 0.5 in.+Days with 1 in.+Freezing nights
Jan2.546.51.6116.1
Feb2.246.81.20.610.1
Mar3.758.62.412.9
Apr3.8282.61.50.2
May5.1510.63.21.90
Jun372.11.20
Jul1.9961.40.50
Aug1.995.31.20.60
Sep2.726.11.60.70
Oct4.36731.40.4
Nov2.93620.74.2
Dec2.786.81.80.812
Year37.2684.724.111.945.9

Source: NOAA daily observations, McKinney National Airport (KTKI), 2005–2025, via RCC-ACIS. Averages per month across 21 years; 36 missing days out of 7,670 were skipped and trace amounts counted as zero. "Freezing nights" are days with a low of 32°F or colder.

What this means for a chimney:

  • May is the wettest month, and March through May together average about 12.7 inches, roughly a third of the year's 37.26 inches. That is also the core of North Collin County's hail season, so spring is when flashing is most likely to be both damaged and tested.
  • October is the second-wettest month at 4.36 inches, with about 1.4 days of 1 inch or more. A flashing gap that stayed hidden through a dry summer can show up with the first heavy fall rain.
  • July and August average about 4 inches combined. A chimney that "stopped leaking" in summer probably just stopped getting wet. Have it looked at before the fall rains, not after.
  • Heavy days are the real test. The airport averages about 11.9 days a year with an inch or more of rain. The wettest single day in the 21 years was November 27, 2015, with 6.55 inches.
  • Years swing hard. 2015 brought 67.3 inches; 2005 brought 19.7. A leak that showed up for the first time in a wet year may have been there for a while.
  • Winter is mostly freezes, not downpours. About 45.9 nights a year drop to freezing, mostly December through February. CSIA notes that common brick soaks up water like a sponge, which is one more reason to keep the cap, crown, and flashing in good repair before winter.

For the same weather data used to plan an inspection, see our roof inspection page.

Wind-driven rain: which side of the chimney gets hit

The Department of Energy's building science guidance frames chimney waterproofing around "controlling rainwater entry during high wind events." Wind turns a gentle rain into water pushed sideways and uphill, straight into the joints between counter-flashing and brick. Two local records show how often that happens near Celina:

  • Storm wind reports. NOAA's Storm Prediction Center database lists 30 days in 2005–2024 with a thunderstorm-wind report within 10 miles of central Celina (28 of them at 58 mph or more). 23 of those days fell between March and June, and 23 of 30 first reports came between noon and midnight. The strongest listed gust was 81 mph.
  • Airport gusts. At McKinney National Airport, 72 days from 2005 to 2025 had a peak gust of 50 mph or more, and 18 reached 58 mph. The last five years (2021–2025) logged 35 of those 50 mph days, compared with 9 in the first five (2005–2009). Station equipment and reporting change over time, so treat that trend with care.

Peak-gust direction on those 50 mph+ airport days (where the station reported one, 72 days):

From northFrom northeastFrom eastFrom southeastFrom southFrom southwestFrom westFrom northwest
126011741616

36 of 72 gusty days came from the west, northwest, or southwest, and 18 from the south or southeast. Easterly gusts were rare. For a chimney, that means the south face and the west-to-northwest faces take most of the wind-driven rain. Practical uses:

  • If your leak log shows water only during storms from one direction, mention which face of the chimney points that way.
  • When a roofer looks at the chimney, ask for photos of all four sides of the flashing, not just the front.
  • On a chimney that sits on a slope facing south or west, the uphill side (and the cricket, if there is one) catches runoff and wind-driven rain at the same time.

Our wind damage guide has the full month-by-month airport gust table and what wind does to shingles. These are station and report records, not a forecast and not a measurement at your house.

After a big storm: a chimney check in the right order

The Chimney Safety Institute of America's Level 2 inspection procedure for masonry chimneys, which follows NFPA 211, says a Level 2 inspection is recommended "if there has been a building or chimney fire, weather or seismic event or any operating malfunction likely to have caused damage to the chimney," and when a property is being sold. That inspection includes going on the roof to look at the crown, flashing, and any cricket, checking the accessible attic for water damage "especially just below the flashing," and a video scan of the flue. A sensible order after hail or a hard wind:

  1. From the ground, the same day: photograph the cap, crown, chase top, and flashing with a zoom lens. Look for a bent or missing cap, displaced flashing, or debris piled behind the chimney.
  2. Inside, during the next rain: check the ceiling and walls around the fireplace and the attic beside the chimney. Add a line to the leak log.
  3. Roofer: flashing, cricket, the shingles around the chimney, and the rest of the roof. Ask for photos of each side. Our roof inspection page explains what a written inspection should include.
  4. Chimney professional: cap, crown, masonry, flue liner, and firebox, before you light a fire again.

If both say the other trade's piece is the problem, ask each to put it in writing with photos. That paper trail matters if the damage turns into a question for your insurer, which is between you and the insurance company.

Hail, wind, and chimneys in Collin County

North Collin County gets regular large-hail days (see our hail season prep guide and the NOAA-based hail history page). After a storm, look from the ground at the chimney cap, any metal chase top, and the flashing for dents, displacement, or bent metal, and photograph what you see. A leak that starts right after a storm is worth documenting separately from an old, slow stain.

The Texas Department of Insurance advises taking pictures and video of the damage, preventing more damage, and saving all receipts because your policy may pay for temporary repairs. Whether chimney or flashing damage is covered is between you and your insurer. We do not help with claims or speak to adjusters; our roof claim prep guide covers the general process.

Newer Celina homes: first-roof chimney details

Most Celina houses are young. In the Census Bureau's American Community Survey 2020–2024 5-year estimates, as shown on Census Reporter's Celina profile, the median year built for Celina's housing units is 2015 and about two-thirds were built in 2010 or later (survey estimates with margins of error). Our Celina growth and roofing demand page has the full table. For chimneys, that means:

  • Many homes are likely still on their original roof and builder-installed flashing. A heavy wind-driven rain can be the first real test of how the step and counter-flashing were done. If a newer home leaks at the chimney, note the date and photograph it right away.
  • Check for a builder warranty before anything else. On a home a few years old, the builder's written warranty may cover workmanship items. Our builder warranty vs. insurance guide explains how to read it, and roofing warranties in Texas covers manufacturer and workmanship warranties.
  • Know what kind of chimney you have. If the "chimney" is framed and clad in siding or stone veneer with a metal top, it is likely a chase for a factory-built fireplace, and the chase pan and storm collar are part of the leak search (see the framed chase section above).
  • HOA rules still apply to repairs you can see. Replacement flashing, a new cricket, or a new chase top may need architectural approval in some neighborhoods. Our HOA roofing guidelines cover the typical submittal, and the Celina neighborhoods roof guide covers local subdivisions.

Re-roofing? Settle the chimney details in writing

A re-roof is the natural time to fix chimney flashing and add a missing cricket, because the shingles around the chimney come off anyway. The IRC's re-roofing section (R908.5) says existing flashings that are part of the roof assembly "shall be replaced where rusted, damaged or deteriorated," and the asphalt shingle section (R905.2.8.4) says chimney flashing is applied according to the shingle manufacturer's instructions. The general flashing section (R903.2.1) calls for corrosion-resistant metal flashing no thinner than 0.019 inch (No. 26 galvanized sheet).

Questions to put to every bidder:

  • Will you replace the step flashing, apron, and cricket flashing, or reuse it? Why?
  • How will the counter-flashing be attached: set into mortar joints or a cut groove, or surface-mounted with sealant?
  • Is the chimney more than 30 inches wide across the slope? If so, is there a cricket now, and will you build or re-flash one?
  • Who handles the cap, crown, or chase top if those are part of the problem?
  • Will you pull the City permit? Inside Celina city limits, the City's Building Services page says a Roof Permit is required for roofing projects, the general contractor must be registered with the City, and a $100 fee applies to each permit request.

Permits and door knockers in Celina

The City of Celina's Building Services page spells out the two permits that matter most after a storm:

  • Roof Permit. Required for roofing projects. The general contractor must be registered with the City and submit a permit request with a completed Residential Minor Permit Application; a $100 fee applies to each permit request. The City's permit applications page says new residential permit applications have gone through the online MGO Connect portal since December 8, 2025, and lists "Residential Roof" as its own permit type.
  • Solicitor Permit. Required for door-to-door business in Celina. The City requires an application, a valid driver's license, and a $100 fee for a background check; an approved permit is valid for one year, and the solicitor gets a badge that must be visibly displayed. If someone knocks after a storm and points at your chimney, ask to see the badge before you talk details.

Homes outside Celina city limits, or in Prosper, Anna, Melissa, or Princeton, fall under a different building department. Prosper, for example, files a re-roof as a Residential Building Remodel permit; see our Prosper page. For the full list of questions to ask any roofer, see our guide to hiring a roofer in Celina.

Not sure whether a leak at the chimney justifies a full roof? Our repair vs. replace guide walks through age, damage spread, and matching. Skylights and chimneys share most of the same flashing logic; our skylight and flashing leaks guide covers the skylight side.

Who to call

  • Roofer: leaks at the roof-chimney joint, missing or sealant-only flashing, a missing or failing cricket, hail-bent flashing, and any re-roof. Ask for a roof inspection or a roof repair quote.
  • Chimney professional (sweep or mason): cap, crown, flue, spalling or cracked brick, mortar joints, waterproofing, and the chase top and storm collar on factory-built units. CSIA says annual chimney inspections and maintenance are best left to a qualified chimney professional.
  • Both: when you can't tell where the water starts. Ask each to document what they found with photos.

Common questions

What is a chimney cricket and does my chimney need one?

A cricket (also called a saddle) is a small peaked roof built on the uphill side of a chimney so rain and debris split around the chimney instead of pooling against it. The model International Residential Code (R903.2.2) requires a cricket or saddle on the ridge side of any chimney or penetration more than 30 inches wide, measured perpendicular to the slope. Celina lists the 2024 IRC among its adopted codes; ask the City or your roofer about any local amendments.

Why does my chimney only leak during some storms?

Wind direction and how hard it rains both matter. Water driven against the uphill face or one side of a chimney can find a gap in step flashing, counter-flashing, or a cracked sealant joint that stays dry in light rain. Write down the date, how hard it rained, the wind direction, and where the stain appears each time; that log helps whoever inspects it narrow down the entry point.

Is caulk or roofing cement a real fix for chimney flashing?

Usually not a permanent one. InterNACHI explains that sealant eventually dries, shrinks, and cracks, and that counter-flashing relying on sealant alone needs ongoing maintenance and should be checked every year. Properly installed counter-flashing on brick is set into the mortar joints (or a cut groove) and then sealed. If a repair plan is only more caulk, ask what is underneath.

My house has a framed chimney with a metal top. Can that leak too?

Yes. Factory-built fireplaces often vent through a framed chase topped with a metal chase pan. The Chimney Safety Institute of America (CSIA) tells sweeps to check chase pans for rust, low spots, or pinholes that let water sit, and to recommend a cricket if the chase is wider than 30 inches and does not meet the ridge. A leak there may be the pan, the storm collar, the siding, or the roof flashing.

Should chimney flashing be replaced when I get a new roof?

Ask about it in every bid. The IRC re-roofing section (R908.5) says existing flashings that are part of the roof assembly shall be replaced where rusted, damaged, or deteriorated, and the shingle sections say chimney flashing goes on per the shingle manufacturer instructions. Inside Celina city limits a Roof Permit is required for roofing projects, pulled by a City-registered general contractor.

Which months put chimney flashing to the test near Celina?

Spring and October. At McKinney National Airport, the nearest long-running NOAA station, May averaged 5.15 inches of rain in 2005 through 2025 and October averaged 4.36 inches, while July and August averaged about 1.99 inches each. A chimney that stayed dry through a hot, dry summer has not really been tested; watch the ceiling after the first heavy spring or fall storms.

Should a chimney be inspected after a hailstorm or windstorm?

The Chimney Safety Institute of America says its Level 2 inspection, which includes going on the roof and into accessible attics and looking for water damage just below the flashing, is recommended after a weather event likely to have caused damage to the chimney, and when a property is being sold. A roofer can look at the flashing and cricket; a chimney professional covers the cap, crown, flue and liner.

How fast do I need to deal with water from a chimney leak?

Quickly. The EPA says to dry water-damaged areas and items within 24 to 48 hours to prevent mold growth, and that if wet materials are dried within that window, in most cases mold will not grow. Catch the drip, move belongings, photograph the stain, and get the source looked at before the next storm.

Can I keep using my fireplace after the chimney leaked?

Ask a chimney professional first. CSIA lists rusted fireplace dampers, rotted wood and cracked flue liner systems among the results of water getting into a chimney, and a cracked liner is a safety issue, not just a stain. Have the flue and firebox checked before the next fire, separately from the roof flashing repair.

Do I need a City permit to fix chimney flashing in Celina?

The City of Celina says a Roof Permit is required for roofing projects, the general contractor must be registered with the City, and a $100 fee applies to each permit request. Since December 8, 2025, new residential permit applications go through the MGO Connect portal. Whether a small flashing-only repair counts as a roofing project is a question for the City permit desk; ask your roofer to confirm it in writing either way.

How Celina Roof Pros fits in

Celina Roof Pros is a free homeowner resource and quote-request service. We send each Celina-area homeowner’s request to one local roofer. We are not a roofing contractor and do not do inspections or repairs ourselves, and we never help with insurance claims or speak to adjusters. When you request a quote, mention the chimney, when the water shows up, which way the wind was blowing, and any photos you have, so the roofer comes ready to look at the flashing and cricket.

Request a free quote. Serving Celina, Prosper, Anna, Melissa and Princeton.

Sources

← All resources · Roof repair · Roof inspection · Skylight leaks · Request a quote

Ready for a clear roofing plan?

Tell us about your roof in Celina or nearby. One local roofer calls you to inspect the roof, document conditions, and explain options. One call, no spam calls, and your info is never sold or shared.